Determination of Mesaconitine,Hypaconitine, Aconitine in Bitong Medicated Wine
|更新时间:2024-01-04
|
Determination of Mesaconitine,Hypaconitine, Aconitine in Bitong Medicated Wine
Chinese Journal of Experimental Traditional Medical FormulaeVol. 18, Issue 22, Pages: 98-100(2012)
作者机构:
作者简介:
基金信息:
DOI:
CLC:
Published:2012
稿件说明:
移动端阅览
FAN Lei-lei, YANG Yan-ling, LIU Nai-qiang, et al. Determination of Mesaconitine,Hypaconitine, Aconitine in Bitong Medicated Wine[J]. Chinese journal of experimental traditional medical formulae, 2012, 18(22): 98-100.
DOI:
FAN Lei-lei, YANG Yan-ling, LIU Nai-qiang, et al. Determination of Mesaconitine,Hypaconitine, Aconitine in Bitong Medicated Wine[J]. Chinese journal of experimental traditional medical formulae, 2012, 18(22): 98-100.DOI:
Determination of Mesaconitine,Hypaconitine, Aconitine in Bitong Medicated Wine
Objective:To establish an HPLC method for determination of mesaconitine
hypaconitine
aconitine in Bitong medicated wine. Method: A Agela Promosil-C18 (4.6 mm×250 mm
5 μm) column was adopted
the mobile phase consisted of acetonitrile-tetrahydrofuran (25∶15
phase A)
0.1 mol·L-1 ammonium acetate(containing 0.5 mL glacial acetic acid per 1 000 mL
phase B) with gradient elution at the flow rate of 1.0 mL·min-1
and the detection wavelength was at 235 nm. Result: The linear range of mesaconitine was 0.118 9 -0.990 9 μg (r =0.999 9). The average recovery was 98.07% with RSD of 1.7%. The linear range of hypaconitine was 0.074 5-0.621 0 μg(r=0.999 9). The average recovery was 99.08% with RSD of 1.5%.The linear range of aconitine was 0.009 4-0.078 3 μg(r =0.999 9). The average recovery was 98.32% with RSD of 2.0%. Conclusion: The developed method was reliable
and can be used for the quality control of Bitong medicated wine.