Determination of Hesperidin in Compound OPG Tablet by HPLC
|更新时间:2024-01-04
|
Determination of Hesperidin in Compound OPG Tablet by HPLC
Chinese Journal of Experimental Traditional Medical FormulaeVol. 9, Issue 1, Pages: 4-5(2003)
作者机构:
作者简介:
基金信息:
DOI:
CLC:
Published:2003
稿件说明:
移动端阅览
SHI Wan-zhong, XU De-sheng, Liu Li, et al. Determination of Hesperidin in Compound OPG Tablet by HPLC[J]. Chinese journal of experimental traditional medical formulae, 2003, 9(1): 4-5.
DOI:
SHI Wan-zhong, XU De-sheng, Liu Li, et al. Determination of Hesperidin in Compound OPG Tablet by HPLC[J]. Chinese journal of experimental traditional medical formulae, 2003, 9(1): 4-5.DOI:
Determination of Hesperidin in Compound OPG Tablet by HPLC
Obective:To develop a HPLC method for determining Hesperidin in the Compound OPG Tablet.Method:The sample was sonicated for 30 min.The contents were determined by HPLC
with a C18 column a molile phare of methanol-water (41∶59) and detection wavelength at 283nm.Result:Hesperidin has a good linearity in the range of 0.05658~1.13μg
Y=2637.54768X-7.43358
r=0.9999
The average recovery is 104.94% and RSD=2.37%(n=5).Conclusion:The method is sensitive
reliable and speedy.It can used for quality control of Compound OPG Tablet.