DU Tian-xin, WANG Xiu-zhen, DU Zhi-qian, et al. Standard of Jiawei Yiqi Pill[J]. Chinese journal of experimental traditional medical formulae, 2013, 19(5): 129-132.
DU Tian-xin, WANG Xiu-zhen, DU Zhi-qian, et al. Standard of Jiawei Yiqi Pill[J]. Chinese journal of experimental traditional medical formulae, 2013, 19(5): 129-132.DOI:
Objective:To improve the quality standard of Jiawei Yiqi Pill. Method: The TLC method was used to identify Angelicae Sinensis Radix
Stephaniae Tetrandrae Radix and Citri Reticulatae Pericarpium in prescription. The HPLC method was used to detect the content of saikosaponin A and D in Bupleuri Radix. Result: This TLC method is good in separation
strong in specificity and negative in interference; saikosaponin A was detected in the range from 0.050 4-0.352 6 mg·mL-1 indicating good linear relationship(r=0.999 7); the mean sample recovery rate was 96.17% and the RSD was 0.18%
and saikosaponin D in the range from 0.034 6 -0.242 3 g·L-1 indicating good linear relationship(r=0.999 3)
the mean sample recovery rate was 96.22% and the RSD 0.16%. Conclusion: The TLC method and HPLC are simple and accurate in operation
high precision and good in reproducibility
and they can be taken as the standard of quality control Jiawei Yiqi Pill.