DING Xiao-yu, CHEN Jun, LIU Yi-dan, et al. Studies on Quality Control Standard of Modified Xileisan Suppository[J]. Chinese journal of experimental traditional medical formulae, 2011, 17(17): 97-99.
DING Xiao-yu, CHEN Jun, LIU Yi-dan, et al. Studies on Quality Control Standard of Modified Xileisan Suppository[J]. Chinese journal of experimental traditional medical formulae, 2011, 17(17): 97-99.DOI:
Objective: To eatablish the quality standard of modified xileisan suppository. Method: Indigo Naturalis
Calculus Bovis
and borneol in this preparation were identified by TLC. The content of indirubin in Modified Xileisan Suppository was determined by HPLC which was performed on a Sino Chrom ODS-AP C18 (4.6 mm×250 mm
5 μm) column with a mobile phase of methanol-1% acetic acid solution (81:19) at a flaw rate of 0.8 mL ·min-1. The UV detection wavelength was 288 nm
and the column temperature was room temperature. Result: Characteristics of identification were very obviously. The linear ranged from 0.2 mg ·L -1 to 10.8 mg ·L-1 (r=0.999 5) and the average recovery was 100.95% (RSD 1.12%
n=6). Conclusion: The method is simple
accurate
good reproducibility
and can be used as quality control for Modified Xileisan Suppository.