HU Nan, LIANG Ri-xin, WANG Lan, et al. Pharmacokinetics Study of Corydalis Extracts in Rat Plasma[J]. Chinese journal of experimental traditional medical formulae, 2011, 17(4): 186-189.
HU Nan, LIANG Ri-xin, WANG Lan, et al. Pharmacokinetics Study of Corydalis Extracts in Rat Plasma[J]. Chinese journal of experimental traditional medical formulae, 2011, 17(4): 186-189.DOI:
同时以 m / z 306~140来检测内标盐酸山莨菪碱(anisodaminehydrochloride
ADM)。CDL
THP分别在1.13~565
1.5~750 ng ·mL-1表现出良好的线性关系
高、中、低3个剂量的回收率、日内和日间精密度均符合要求
不同剂量THP和CDL的Cmax分别为(84.3±9.2)
(157.3±99.6)
(497.1±71.3) ng ·mL-1和(30.8±1.3)
(54.4±22.7)
(91.2±15.4) ng ·mL-1
Tmax分别为(54.8±6.9)
(119.2±5.7)
(62.5±7.5) min和(31.5±0.07)
(65.6±10.6)
(111.5±4.2) min。 结论 : LC-MS/MS选择性好
灵敏度高
适用于血浆样品成分含量的测定
为进一步的复方药代动力学的研究奠定了基础。
Abstract
Objective: To investigate pharmacokinetics process of the major components of the extract Corydalis tetrahydropalmatine (tetrahydropalmatine
THP)and d-corydaline (corydaline
CDL)in rats. Method: Using LC-MS/MS to measure plasma concentration at different time after ig administration concentration of Corydalis extracts was determined
WinNonlin software was used to calculate pharmacokinetic parameters. Result: ESI (+)ions under the condition of using MRM mode with m/z370-354
m/z 356-340 was used to detecte CDL
THP
while the m/z 306-140 was used to detect the internal standard anisodamine (anisodaminehydrochloride
ADM). In the range of 1.13-565
1.5-750 ng ·mL-1
CDL
THP showed good linearity
high
medium and low recovery rates of THP
and CDL
day and inter-day precision met the demands of quantification
Cmax were (84.3±9.2)
(157.3±99.6)
(497.1±71.3)ng ·mL-1 and (30.8±1.3)
(54.4±22.7)
(91.2±15.4)ng ·mL-1
Tmax were (54.8±6.9)
(119.2±5.7)
(62.5±7.5)min and (31.5±0.07)
(65.6±10.6)
(111.5±4.2)min. Conclusion: LC-MS/MS had good selectivity
high sensitivity for the determination of plasma sample.