LIU Ling-an, YANG Hua, GAO Xiao-hui, et al. Study on Formulation Technology of Simotang Dropping Pills[J]. Chinese journal of experimental traditional medical formulae, 2011, 17(3): 46-48.
LIU Ling-an, YANG Hua, GAO Xiao-hui, et al. Study on Formulation Technology of Simotang Dropping Pills[J]. Chinese journal of experimental traditional medical formulae, 2011, 17(3): 46-48.DOI:
Objective: To establish the optimized preparation of Simotang dropping pills. Method : The optimum extraction process was selected with Single-factor test and orthogonal
taking difference of pill mass
dissolution and the shape of pill as indicators
and through examing the dropping temperature
dropping speed and external diameter of burette to select the best dropping conditions. Result: The best dropping conditions was that the dropping temperature was at 75 ℃
dropping speed was 30 to 40 drops per minutes
internal and external diameter of burette are 2.0 mm and 5.0 mm. Conclusion: The formulation technology is suitable for industrial production.