ZHAO Yu-xin, LI Man-ling. Determination of Arginine in Fort.Using HPLC with Evaporative Light-Scattering Detector(ELSD)[J]. Chinese journal of experimental traditional medical formulae, 2004, 10(1): 8-9.
ZHAO Yu-xin, LI Man-ling. Determination of Arginine in Fort.Using HPLC with Evaporative Light-Scattering Detector(ELSD)[J]. Chinese journal of experimental traditional medical formulae, 2004, 10(1): 8-9.DOI:
Objective:To establish a method for the determination of arginine in Isatis indigotica Fort.Method:Chromatography was performed on a 4μm Luna C18 column (4.6mm×150mm)at 25℃.The mobile phase was composed of water-trifluoroacetic acid(99.8∶0.2)with a flow rate of 0.2ml5min-1.An Alltech-500 evaporative light-scattering detector(USA)was used with a gas flow rate of 3.00 L5min-1 and tube temperature of 105℃.Result:A good relationship between logarithm of peak area and logarithm of concentration was noted at 0.504μg~2.52μg.Average recovery of arginine was 99.30% and the RSD was 0.87%.Conclusion:It was proved that the method was reliable