Determination of Trace Amount Lead,Niccolum,and Cadmium in Oficinal Magnesium Stearate with Microwave Digestion and Flame-atomic Absorption Spectroscopy
WEI Hui-zhen1, LV Shang1, RAO Yi1, et al. Determination of Trace Amount Lead,Niccolum,and Cadmium in Oficinal Magnesium Stearate with Microwave Digestion and Flame-atomic Absorption Spectroscopy[J]. Chinese journal of experimental traditional medical formulae, 2011, 17(5): 98-101.
WEI Hui-zhen1, LV Shang1, RAO Yi1, et al. Determination of Trace Amount Lead,Niccolum,and Cadmium in Oficinal Magnesium Stearate with Microwave Digestion and Flame-atomic Absorption Spectroscopy[J]. Chinese journal of experimental traditional medical formulae, 2011, 17(5): 98-101. DOI: 10.13422/j.cnki.syfjx.2011.05.054.
Objective:Set up a flame-atomic absorption spectroscopy method with cadmium
niccolum
and lead in oficinal magnesium stearate.Method:Oficinal magnesium stearate disposed via microwave digestion or ac-customed digestion
adopting Flame-Atomic Absorption Spectroscopy to determine trace amount lead
niccolum
and cadmium
and review the influence of determination from both disposal.Result:The result of determination by micro-wave digestion is better than accustomed digestion.The results of determination are as follows:cadmium was 0.42-1.12 mg·L-1
niccolum was 3.80-4.06 mg·L-1
lead was 5.07-10.31 mg·L-1.The limit of determination of cad-mium
niccolum
and lead are 0.001 2
0.002 9
0.003 4 mg·L-1
the RSD are 0.2%
2.9%
2.7%
the recovery are 109.18%
101.30%
99.69%.Conclusion:This method possesses excellence of simplify manipulation
high ve-racity and nicer repeatability.It can content the need of trace amount
cadmium
niccolum
and lead determination and offer basis for quality control of oficinal magnesium stearate.