HUO Xin1, HUANG Xiao-qi2, LIU Jian-hua1, et al. Establishment and Validation of Microbial Limit Method for Xiaochuan Tablets[J]. Chinese journal of experimental traditional medical formulae, 2012, 18(15): 121-124.
HUO Xin1, HUANG Xiao-qi2, LIU Jian-hua1, et al. Establishment and Validation of Microbial Limit Method for Xiaochuan Tablets[J]. Chinese journal of experimental traditional medical formulae, 2012, 18(15): 121-124. DOI: 10.13422/j.cnki.syfjx.2012.15.090.
Objective: To establish the validation of microbial limit test method for Xiaochuan tablets.Method: The microbial limit test mothod of Xiaochuan tablets was validated using Escherichia coli
Bacillu Subtilis
staphy lococcus aureus
Aspergillus niger and Candida albicans according to Chinese Pharmacopoeia Edition 2010.Result: Xiaochuan tablets has a strong inhibition on Staphylococcus aureus and Bacillus subtilis.Conclusion: Medium dilution method were used with count of bacterium.The routine method were used with counts mold and yeasts.Pathogenic bacteria can be tested when general method were used.The method is cogent
effective and can be used to the quality concrol of the Xiaochuan tablets.