LIU Bin, SHI Ren-bin, ZHOU Ying, et al. Determination of Peimine and Peiminin in Capsule[J]. Chinese journal of experimental traditional medical formulae, 2001, 7(4): 8-10.
LIU Bin, SHI Ren-bin, ZHOU Ying, et al. Determination of Peimine and Peiminin in Capsule[J]. Chinese journal of experimental traditional medical formulae, 2001, 7(4): 8-10.DOI:
The contents of peimine and peiminine in Beilexin capsule were determined with TLCS. The results showed that the linear range was 1.99μg~9.95μg for peimine and 2.00μg~10.00μg for peiminine
respectively. This method was used to determine peimine and peiminine in Beilexin capsule with recovery of 101.5% and 98.5%
respectively. The contents of peimine and peiminine of three batches of samples were determined with this method.