LI Chang-qin, LI Dan, WANG Pei-qing, et al. Determintion for Content of Puerarin in Three Kinds of Puerarin Injections by HPLC Method[J]. Chinese journal of experimental traditional medical formulae, 2014, 20(24): 60-63.
LI Chang-qin, LI Dan, WANG Pei-qing, et al. Determintion for Content of Puerarin in Three Kinds of Puerarin Injections by HPLC Method[J]. Chinese journal of experimental traditional medical formulae, 2014, 20(24): 60-63. DOI: 10.13422/j.cnki.syfjx.2014240060.
Objective: An HPLC method was established to determine the content of pueratin in three types of injection. Method: Separation was achieved by a Merk
Purospher STAR RP-C18 column used at 29 ℃
and mobile phase was methanol and 1% acetic acid
water with the flow rate of 1.0 mL·min-1
detection wavelength of 250 nm. Result: The puerarin was separated with good linearity in the sample size range of 0.192-1.152 μg. The average recovery was 99.81%
with RSD value of 0.42%. Conclusion: The puerarin in three types of puerarin injection could be well separated under the selected conditions
showing good linear relationship. The method was simple and quick
feasible and could provide scientific basis for the quality control of puerarin injection.